EEC
High-Speed Bio Tec™
Let DAS take care of your wastewater
with the most compact and reliable
Bio systems ever built. Compare
most other Bio Systems with 20 hours
retention time to two (2) hours.
EEC Bio systems can handle shock
loading, pH variation, is clog-free,
extremely compact, and once started
up, very stabile operation.
WORLD
WIDE INSTALLATIONS - The
EEC Bio systems are manufactured
in Brazil, Europe, India, South
Africa, and the USA, with installations
and service in every corner of the
world. The systems are extremely
compact, skid mounted, automatic
operation, one central location
for all controls, and require minimum
attendance once in operation.
EEC
HIGH-SPEED BIO TEC. Constructed
for Domestic Wastewater (Sewer)
and Industrial wastewater. And can
be customized to your specifications,
water can be recycled, used for
cleaning, toilet flushing, or surpass
any effluent requirements. We produce
systems for both ammonia and nutrient
removal if so required.
LEASE
OR BUY with worldwide production,
service and delivery, we assure
you quick delivery, quality production,
and competitive prices, or we can
discuss lease contracts.
SPECIFICATIONS
The
EEC Condo STP system is based on
the EEC High-Speed Bio-Tec biodegradation
and sedimentation technology which
is unique due to its compactness
and performance in respect of volumetric
efficiency. These technologies are
combined in a prefabricated, skid
mounted, and standardized tank system
with variable length, suitable for
overseas transportation in ISO freight
containers.
Standard
systems are designed for indoor
locations in closed rooms with draft
ventilation. Smaller systems may
be placed outdoors under shelter
with natural ventilation. Since
the systems are excessively aerated,
the smell caused by anaerobic rotting
is negligible.
DIMENSION
CRITERIA
Every
treatment plant should be based
on actual measurements of the waste
stream to be treated in respect
of hydraulic load, suspended and
dissolved organic material, and
the applicable local effluent requirements.
However, sufficient statistical
information is available for small
community municipal waste water,
related to the term "Person
equivalents" (Pe)
CAPACITIES
The
Condo STP system is manufactured
in lengths of 2 feet increment in
order to suit any particular need.
The basic 15', 21', 27’, 33’
and 39' length systems with 3 chambers,
have following nominal capacities
at a guaranteed effluent of 30 ppm
BOD as daily average
Model:
15CON3
21CON3
27CON3
33CON3
39CON3
Capacity
Per/Day
100
m3/d
150
m3/d
200
m3/d
250
m3/d
300
m3/d
Systems
with requirements to effluent COD
will normally require longer retention
time and will consequently have a
lesser capacity then above. Such systems
will be designed as customized systems
based on the customers influent analysis.
PRE-SEDIMENTATION
SYSTEM
It
is assumed that the sewage piping
system ends in a customer provided
three-chamber combined sedimentation/buffer/pump
well tank system which separates
paper, sanitary binds, and settleable
solids. The buffer capacity must
be sufficient to level out the daily
peak flows. The combined holding
capacity of the system should be
12-16 hours, depending of the flow
profile. 5/8 of the volume is for
primary sludge sedimentation, 2/8
of the volume is for secondary sedimentation
and 1/8 is for the pump well. The
total buffer capacity is 1/2 of
the total volume, the remaining
is for sludge storing.
BIOLOGICAL
TREATMENT SYSTEM
The
treatment plant will take suction
from the pump well by its own feed
pump. The pump is level controlled
and has a capacity which is 2-3
times the average daily flow. The
plant has therefore an intermittent
working mode in terms of hydraulic
flow, while the air blower supplying
air to the bioreactors is continuously
running.
The
biodegradation reactor comes in
one or two stages depending on required
cleaning efficiency. Plants with
higher cleaning efficiency than
80-85 % need a two stage system.
The bioreactors are degrading the
dissolved organic matter by oxidation
into carbon dioxide which escapes
to the air, and to produced biomass
which act as activated sludge. A
suspended, free floating biofilm
carrier medium is providing a large,
protected biofilm surface as host
for the bacteria and is simultaneously
accumulating the active biosludge
inside the reactors.
The
biodegraded water is flowing into
a clarification stage where the
suspended solids settle by gravity.
The water is directed through a
skim well to a plate settler system
which provides the final clarification
of the effluent For systems with
high cleaning efficiency, the sedimentation
may be enhanced by addition of polymers.
THREE
CHAMBER SYSTEM
Equipment
Specification
Unit
15CON3
21CON3
27CON3
33CON3
39CON3
Tank
Container
Overall
Length
Inches
180
252
324
396
468
Overall
Width
Inches
88
88
88
88
88
Overall
Height
Inches
88
88
88
88
88
Bio Medium
AMB
Bio Media
Electrical
System
Installed
effect
kW
4
4
5
6
7
Shipping
weight
Dry
weight
kg
3000
3800
4600
5400
6200
Operation
weight
Water
filled
kg
18000
26300
34600
42900
51200
Larger
models are available upon request.
EEC's Research and Development team
is continuously updating our technology
and specifications