No more about the leters news.

 

Cásper Líbero, St. 954
Paulicéia - SBC - SP
(11) 4173 1500



COMPACT PACKAGE PLANTS FOR SEWER AND INDUSTRIAL

EEC High-Speed Bio Tec™ Let DAS take care of your wastewater with the most compact and reliable Bio systems ever built. Compare most other Bio Systems with 20 hours retention time to two (2) hours. EEC Bio systems can handle shock loading, pH variation, is clog-free, extremely compact, and once started up, very stabile operation.

WORLD WIDE INSTALLATIONS - The EEC Bio systems are manufactured in Brazil, Europe, India, South Africa, and the USA, with installations and service in every corner of the world. The systems are extremely compact, skid mounted, automatic operation, one central location for all controls, and require minimum attendance once in operation.

EEC HIGH-SPEED BIO TEC. Constructed for Domestic Wastewater (Sewer) and Industrial wastewater. And can be customized to your specifications, water can be recycled, used for cleaning, toilet flushing, or surpass any effluent requirements. We produce systems for both ammonia and nutrient removal if so required.

LEASE OR BUY with worldwide production, service and delivery, we assure you quick delivery, quality production, and competitive prices, or we can discuss lease contracts.


  SPECIFICATIONS
The EEC Condo STP system is based on the EEC High-Speed Bio-Tec biodegradation and sedimentation technology which is unique due to its compactness and performance in respect of volumetric efficiency. These technologies are combined in a prefabricated, skid mounted, and standardized tank system with variable length, suitable for overseas transportation in ISO freight containers.
Standard systems are designed for indoor locations in closed rooms with draft ventilation. Smaller systems may be placed outdoors under shelter with natural ventilation. Since the systems are excessively aerated, the smell caused by anaerobic rotting is negligible.
DIMENSION CRITERIA    

Every treatment plant should be based on actual measurements of the waste stream to be treated in respect of hydraulic load, suspended and dissolved organic material, and the applicable local effluent requirements. However, sufficient statistical information is available for small community municipal waste water, related to the term "Person equivalents" (Pe)

CAPACITIES
The Condo STP system is manufactured in lengths of 2 feet increment in order to suit any particular need. The basic 15', 21', 27’, 33’ and 39' length systems with 3 chambers, have following nominal capacities at a guaranteed effluent of 30 ppm BOD as daily average
Model:
15CON3 
21CON3 
27CON3
33CON3

39CON3

Capacity Per/Day
100 m3/d 
150 m3/d 
200 m3/d
250 m3/d

300 m3/d

         

 

         

 

Systems with requirements to effluent COD will normally require longer retention time and will consequently have a lesser capacity then above. Such systems will be designed as customized systems based on the customers influent analysis.
PRE-SEDIMENTATION SYSTEM

It is assumed that the sewage piping system ends in a customer provided three-chamber combined sedimentation/buffer/pump well tank system which separates paper, sanitary binds, and settleable solids. The buffer capacity must be sufficient to level out the daily peak flows. The combined holding capacity of the system should be 12-16 hours, depending of the flow profile. 5/8 of the volume is for primary sludge sedimentation, 2/8 of the volume is for secondary sedimentation and 1/8 is for the pump well. The total buffer capacity is 1/2 of the total volume, the remaining is for sludge storing.

BIOLOGICAL TREATMENT SYSTEM

The treatment plant will take suction from the pump well by its own feed pump. The pump is level controlled and has a capacity which is 2-3 times the average daily flow. The plant has therefore an intermittent working mode in terms of hydraulic flow, while the air blower supplying air to the bioreactors is continuously running.

The biodegradation reactor comes in one or two stages depending on required cleaning efficiency. Plants with higher cleaning efficiency than 80-85 % need a two stage system. The bioreactors are degrading the dissolved organic matter by oxidation into carbon dioxide which escapes to the air, and to produced biomass which act as activated sludge. A suspended, free floating biofilm carrier medium is providing a large, protected biofilm surface as host for the bacteria and is simultaneously accumulating the active biosludge inside the reactors.

The biodegraded water is flowing into a clarification stage where the suspended solids settle by gravity. The water is directed through a skim well to a plate settler system which provides the final clarification of the effluent For systems with high cleaning efficiency, the sedimentation may be enhanced by addition of polymers.

 

THREE CHAMBER SYSTEM
Equipment
Specification
Unit

15CON3

21CON3

27CON3

33CON3

39CON3

               
Tank Container
Overall Length
Inches

180

252

324

396

468

 
Overall Width
Inches

88

88

88

88

88

 
Overall Height
Inches

88

88

88

88

88

               
Bio Medium AMB Bio Media            
               
Electrical System
Installed effect
kW

4

4

5

6

7

               
Shipping weight
Dry weight
kg

3000

3800

4600

5400

6200

               
Operation weight
Water filled
kg

18000

26300

34600

42900

51200